AGILENT 66XXA DRIVER

Legal Privacy Terms Trademark Acknowledgements. Poorly designed linears can have commutating spikes when their bridge rectifier diodes turn off. An example is testing an automotive component at a high voltage 14V, a nominal voltage of 12 V and a low voltage of 10V. Active loads that create a sinking current should not be connected to a power supply. However, there is an exception for one series of Keysight power supplies. Calibration Certificates Criteria have been established to determine which products get or do not get a calibration from the factory. The downloadable at the right indicates the type of each model of power supply that Keysight has offered recently.
Uploader: Maurn
Date Added: 13 October 2018
File Size: 60.43 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 97748
Price: Free* [*Free Regsitration Required]





66xxA: Down programming | Keysight (formerly Agilent’s Electronic Measurement)

Other vendors also supply old manuals. Stored energy from the power supply's output capacitor and external capacitance from the load including the wiring must be dissipated to lower the voltage at the output terminals.

This also includes the power supplies output relay. Sinking, or down-programming, is the ability to 66xa current into the positive terminal of power supply. Sinking is provided to improve a power supply's transition time from a higher to a lower constant voltage level, and is not intended to be a steady-state operating condition.

Yes, many Keysight power supplies feature remote voltage programming or analog programming capability. Power supply oscillation can occur when driving an inductive load or magnet. Inductive loads present no stability problems in the CV mode, however, in the CC mode a parallel resonant network is formed by the inductance of the load and the output capacitance of the power supply.

Some power products use lots of power, far beyond the range of typical electronic products with which we are familiar. Peak-to-peak noise is measured from the maximum positive point on the agilnt to the most negative voltage point. This can cause ringing, or even oscillation at a frequency given by the formula: Test times in which a DUT is tested at several output voltages will be improved. However, there is an exception for one series of Keysight power supplies. An example is testing an automotive component at a high voltage 14V, 666xxa nominal voltage of 12 V and a low voltage of 10V.

Down programming FAQ See search results instead: The resultant voltage for series connections cannot exceed the maximum floating voltage allowed for any on the component power supplies. So as not to unfairly prejudice customers on the performance of these supplies, we have avoided blatantly labeling them as switchers. Today, all Keysight power supplies offer very low p-p ripple and noise specifications, and very low radiated and conducted EMI.

Which Power Supplies are Switchers, and Which are Linears?

Legal Privacy Terms Trademark Acknowledgements. There are no components used in Power Products which have a specific shelf life. However, many switching supplies are still available from other manufacturers that do not offer this level of performance.

Calibration Certificates Criteria have been established to determine which products get or do not get a calibration from the factory. Programmable Current Sinking In general, current sinking is a fixed value at some percentage of the full scale current output.

However, there are a couple of problems that can arise in these applications. In fact, Keysight switchers can be quieter than some linears! Test times will also be improved in a system where the supply is switched ayilent the power supply is set to zero before the supply is switched. Programmable Current Sinking In general, current sinking is a fixed value at some percentage of the full scale current output.

agilenf Ca Keysight power supplies be programmed from 0 to full output voltage using a 0 to 10V signal source?

A agillent with a product number does not automatically qualify for a calibration certificate. Contact an Expert Chat Live.

The resultant voltage for series connections cannot exceed the maximum floating voltage allowed for any on the component power supplies.

However, Keysight pioneered switching supplies such as the series which offered the performance of linears with the advantages of switchers.

How can I drive an inductive load or a large electro-magnet with a power supply?

Some power products use lots of power, far beyond the range of typical electronic products with which we are familiar. If you are getting either error 11 or error when you try to send GPIB commands to your system supply, it may be that you are using the wrong command language. On the xB series, the maximum negative current tracks agileng value programme

Comments

Popular posts from this blog

MOVIMAX D300 DRIVER

DATALOGIC QS6000 PLUS SCANNER DRIVER